| Customization: | Available |
|---|---|
| Warranty: | 1 Years |
| Pulse Type: | Negative Square Wave Pulse |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Launch parameters | Launch parameters |
| Pulse type | negative square wave pulse |
| Transmitting pulse voltage | 200V-400V |
| Pulse front | <10 ns |
| Pulse width ranging | 30ns to 1000ns |
| Impedance matching | 48 Ω, 500 Ω |
| Receive parameters | Receive parameters |
| Sampling frequency/bit count | 400MHz/10bits |
| Sampling depth | 512 |
| Signal bandwidth | 0.5MHz-30MHz |
| Equivalent input noise | <60nV/√ Hz |
| Repetition frequency | 15Hz-1000Hz |
| Attenuator accuracy | < ± 1dB/12dB |
| Gain range/step size | size 120dB/0.1dB, 1dB, 2dB, 6dB (fully automatic adjustment) |
| Speed range | (300-20000) m/s |
| Dynamic range | ≥ 36dB |
| Vertical linear error | ≤ 2% |
| Horizontal linear error | ≤ 0.1% |
| Overall performance | Overall performance |
| Resolution | > 32dB |
| Sensitivity margin | ≥ 65dB(Φ2×200mm) |
| Working methods | Single crystal flaw detection, twin crystal flaw detection |
| Detection methods | full detection, positive detection, negative detection, RF detection |
| Instrument parameters | Instrument parameters |
| Overall dimensions | 266 × 164 × 48 (mm) |
| Whole machine weight | 1.25Kg (including battery) |
| Display screen size | 5.7" |
| Display screen resolution | 640 × 480 |
| Power supply and battery | DC (DC12V/3.34A) |
| Battery | 7.4V/10.2Ah |
| Battery life | continuous operation for more than 8 hours (powered by lithium battery) |
| Interface | WIFI,USB2.0,VGA,OTG |
| Environmental temperature | (-10-40) ºC (reference value) |
| Relative humidity | (20-95)%RH |
| Application | Ultrasonic testing and thickness measurement of welds and motherboards in boilers, pressure vessels, pipelines, and various metal components |
|