Customization: | Available |
---|---|
Warranty: | 1 Years |
Automatic Grade: | Semiautomatic |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
One-click identification of strange waves, accurate detection of defects without interference from phantom waves when inspecting long workpieces, making inspection easier
Bottom wave internal display, no matter how big the difference between bottom wave and damage wave is, they can be displayed on the same screen
Local widening function, showing more waveform details, focusing on your attention
DAC, AWS, DGS curves can be switched freely to meet the requirements of different modes and standards,
Transmit parameters | |||
User interface language | Chinese | Power supply type | DC15V adapter power supply, 11.1V/6600mA lithium battery power supply |
Storage space | 8G SD card, expandable to 64G | Display type | 6.5-inch LED LCD screen |
Capacity | 2.4kg | Display resolution | 640x480 |
Human-computer interaction | Shuttle, keyboard | Overall size (width x height x thickness) | 248x180x80 (mm) |
Color | green | ||
Instrument interface | |||
Flaw detection interface | C9*2 | USB ports | 2 USB 2.0 |
I/O interface | 2-way encoder interface | Video output | 1 VGA |
Communication interface | 1 RJ45 network port | Power interface | Standard 2.5mm DC interface |
Pulse generator | Adjustable negative square wave | Emitting voltage | 300 V-800 V |
Pulse repetition frequency | (PRF) 15Hz~1000Hz | Pulse width | 30ns-1000 ns |
Transmitter damping | 50 Ω, 500 Ω | ||
Receiver | |||
Sampling frequency | 200MHz/10bits | Detection | Full wave, positive half wave, negative half wave, RF wave |
Sampling depth | 512 | Gain range/adjustment step | 120dB/0.1dB |
Receiver bandwidth | 0.5-30MHZ, at -3dB | Horizontal linearity | 0.2%FSW |
Equivalent input noise | ≤80nW/√Hz | Amplitude measurement | 0.4%-100%FSH |
Vertical Linear | 3%FSH | Attenuator accuracy | <±1dB/20dB |
Comprehensive performance | |||
Resolution | 39dB | Sensitivity margin | 62dB |
Standard Configuration | |||
Name | Specifications | Unit | Quantity |
Ultrasonic detector for castings and forgings | HS512 | Unit | 1 |
Homemade lithium battery | 11.1v/6600mA | Block | 2 |
Portable work belt1 | / | Piece | 1 |
Power cord | 220V | Root | 1 |
Adapter | 15V/90W | Piece | 1 |
Network cable reel probe | 1.5M | Root | 1 |
Disc | 16G | Piece | 1 |
Probe | 1.25MHz φ28mm | Pcs | 1 |
Probe cable | C9-Q9-2000 | Root | 2 |
Instrument protection box | 'PC-5622W | Piece | 1 |
Special for castings and forgings